Dental Laboratory
|
|
KaVo Dental GmbH Bismarckring 39 88400 Biberach/Riß Fon: +49 73 51 / 56-0 Fax: +49 73 51 / 56-14 88 info@kavo.com |
12 kg is the average dust load of hazardous substances that a dental technician receives per year.
Very great danger lurks in very fine
dust. What are very fine dusts?
Dust particles which can enter
the lungs and have a size between 0.01 and 1 µm. Whether
cobalt, nickel, beryllium or quartz, dental technicians
who do not use a perfect dust extraction system are living
dangerously. However, substances such as plaster, gold or
plastic also impair the health of your employees.
The articulator from KaVo
The innovative evolution of articulators is called KaVo PROTARevo, which sets new standards in the market. Our designers have further developed KaVo’s typical, striking use of shapes and optimised functionality to a high
level.
The result is articulators, which by their nobledesign and colouring
hygiene and value, communicate
almost by themselves.
Be inspired by the extra values of the PROTARevo
perfect precision their cost effectiveness
convincing presentation of your prosthetic work to the patient
superior handling
KaVo PROTARevo the top of the line.
You sense the quality
in every detail. From the simple, asic model PROTARevo 2 up to the top model
PROTARevo 9 for splint therapy. Whichever model
you actually choose for your laboratory
or practice, you will always take
the right decision for quality and
cost-effectiveness combined with a functional, winning design.
Take advantage of the added valve
Perfect precision, superior economy Attractive presentation of your prosthetic work on the patient Easy handling
Transfer stand (0.622.1141)
Used for mounting the maxillary
cast in the articulator in the laboratory with the aid of
the joint piece (0.622.0901) of the ARCUS facebow. The facebow
can thus remain in the practice.
Present high quality
Alongside perfect precision
and first class finishing of the prosthesis,
presentation to the patient is becoming
more and more important. KaVo has
placed this decisive aspect in the centre of the new
development. The
matt silver surfaces denote a high level
of hygiene in the dental surgery and laboratory. This
is underlined by the high quality appearance
and elegant use of shapes in the design.
Mounting plate with split cast (0.622.0791)
Mounting plate usable as often as desired and with flank-centred split cast. For all PROTAR articulators with mounted magnet split cast. 10 units in each package.
ZMK (21) 10/2005: Dr. Wolfgang Bernd Hannak
From a wax bite registration to the ARCUSdigma, electronic registration systems as tools (pdf, 251 kB).
For more information about (new) Everest products, visit http://www.kavo-everest.com
The world's best laboratory drives
More grip
Soft zones with recessed grip areas.More cooling
20% less heating of the handpiece.More flexibility
33% smaller cable diameter and hence 60% lower weight.
Overview of publications and articles in books
The list contains 40 publications about the KaVo PROTAR and ARCUS system as well as 6 book articles (pdf, 16 kB).
Video PROTAR System
Introduction to the handling of the PROTAR articulator
and the ARCUS facebow.
German: VHS/PAL (1.000.4154).English: VHS/PAL (1.000.4155)
and VHS/NTSC (1.000.4156).Other languages available on request.
Retention adapter
The retention adapter can be snapped onto the mounting plate. This permits simple impression of the plaster cast and repositioning.
10 pieces (1.001.0882)
50 pieces (1.001.0953)
Design
The elegant design of the KaVo PROTARevo
presents the finished prosthesis at
the highest level. The design of the PROTARevo, with
a variety of working positions, makes it particularly suitable
for the setting up of full dentures.
Orbital plane guide for non-KaVo facebows (0.622.1151)
The orbital plane guide for non-KaVo facebows, together with the transfer stand, permits the use of facebows from other manufacturers on the PROTAR system. The upper component indicates the reference plane for the Frankfurt horizontal plane. The lower component serves as a support for the respective facebow.
Presentation
A presentation
of the technical
work in the
articulator is essential for your success.
Whether the discussion regarding the prosthesis
takes place between the dental
technician and
the dentist, or between dentist
and patient, the
surroundings are always
in the field of vision.
The clinical appearance of
the PROTARevo leaves no doubt about the hygienic surroundings
in the surgery or laboratory.
StartPROTAR evo 2PROTAR evo 3 ?="" border="0" height="119" width="175" />
?="" border="0" height="119" width="175" />
Saggital
Condylar
pathFix
30° zur CE
45° zur FHFix
30° zur CE
45° zur FH
Horizontal
Condylar path
(Bennett)Fix
15°Fix
15°Horizontal
Condylar path
(Iss)0 mm0 mmHorizontal
Condylar path
Shift angle0°0°Protrusion--Retrusion--Distraction--Occlusal CorrectionsHighHigh
Features
Light, hygienic metal surface. Smooth surface with fewer corners and edges for easy
cleaning. Lower weight through new production
process. Larger scale for inclination
of joint path and hence more precise programming. Magnetic fastening of the model
even without split cast.
Progress in drives
KaVo has consistently developed the convenient and at the same time
powerful laboratory drives. K-POWERgrip, K5plus and K4plus have now resulted in a new generation
of laboratory drives which enable their users to work optimally in every
respect. Thanks to their new motor technology, which produces a 20% lower surface
temperature, these up-to-date KaVo handpieces are convincing by providing
yet more convenience - even in continuous operation and under high load.In terms of torque, probably the most important performance criterion
for laboratory drives, the K-POWERgrip sets a standard.Moreover, the number of components has been minimised in all KaVo laboratory
drives. This ensures that KaVo handpieces are entirely customer-friendly
in service and maintenance. An important contribution to the profitability of your laboratory. And if your KaVo handpiece should in fact be "ready for the workshop",
for example because certain components are subject to mechanical wear,
KaVo After-Sales service guarantees fast and professional handling of
all repairs and short throughput and maintenance times. Dental technicians worldwide rely on KaVo. You know
why.
Comfort and vitality KaVo's laboratory furnishing ranges combine functionality,
ergonomics, a long life and outstanding appearance into a new, harmonious
workplace. IndividualityWishes take shape - dreams come true. A laboratory which
suits you. Functionality
Whatever your position - your KaVo furnishings always work hand
in hand with you.. Maintenance of value
KaVo means quality. Selected material tested for work in the laboratory
will always be there for you.
Why are very fine dusts hazardous
to health?
The lung is particularly at risk from very
fine dusts. The very small particles penetrate deep into the
alveolar region of the lung and remain firmly fixed there.
Here, they lead to tissue changes and scarring (pneumoconiosis)
and can cause skin allergies.Concentrations above certain limits can have fatal effects
on the human body, for example poisoning or cancer.How can you protect yourself from
this?
Good dust extraction is essential. The use of a tailored suction
hood with safety screens provides even more protection.
What criteria should be observed for dust extraction systems?
The suction power: not too little, not too much. The separation (in %) depends on the filter. All KaVo dust
extraction systems have a 3-filter system.
Premium PROTAR evo 5 PROTAR evo 5B ?="" border="0" height="119" width="175" />
?="" border="0" height="119" width="175" />
Saggital
Condylar
pathadjustable
-10 bis 90° (FH)
-25 bis 75° (CE)adjustable
-10 bis 90° (FH)
-25 bis 75° (CE)Horizontal
Condylar path
(Bennett)fixed
15°adjustable
0-30°Horizontal
Condylar path
(Iss)0 mm0 mm
Horizontal
Condylar path
Shift angle0°0°Protrusion--Retrusion--Distraction--Occlusal CorrectionsMediumMinimum
Precision
The success of a dental prosthesis is strongly
connected with its precision. The fit on the
tooth stump and the construction of the
occlusal surfaces have a
large bearing on its life
span.
Precision of the occlusal surface is dependent on
precision articulators in the
hands of an experienced dental technician.
Denar adapter (0.622.1351)
The Denar adapter permits the use of the
Denar facebow. In this case, the complete joint piece of
the Denar facebow is positioned correctly in the PROTAR.
For this purpose, the Denar adapter is inserted instead
of the incisal pin into the lower part of the articulator.
Precision I
Optimum setting of the patient’s data
by use of the large dimension adjustment scale.
Mounting plates for PROTARevo 3PS (1.002.2096)
Mounting plates usable as often as required with 3PS alignment system for PROTARevo 3PS artikulators. 10 units in each package.
Publications through PROTAR and ARCUS
ZMK (21) 10/2005: Dr. Wolfgang Bernd Hannak
On the wax bite registration to the ARCUSdigma, electronic registration systems as a tool
Overview of publications and book articles
This list contains 40 publications on the KaVo PROTAR and ARCUS system as well as 6 book articles.
Book articles
1. Implant prosthetics
Publisher: Neuer Merkur ISBN 3921280-982
2. Implant aesthetics
Author: P and L. Rutten, publisher: Neuer Merkur
Retention adapter for 3PS mounting plate (1.003.2868)
The retention adapter can be snapped onto the mounting plate. This permits simple impression of the plaster cast and repositioning.
Precision II
Experience precision in the smallest detail.
Rigid centric lock of Inox steel for
perfect static occlusion.
Panadent pointer (0.622.1371)
Permits the use of the Panadent facebow. For this purpose, the Panadent pointer is mounted on the infraorbital pointer of the Panadent bow. The Panadent facebow is then oriented with the Panadent pointer relative to the patient's infraorbital point.
Handling
Surfaces and shapes
to get hold of. The new
PROTARevo.The unique design follows
the laws of ergonomics.For each stage in the process
there is a defined
position for the articulator. The optimum view is
unique, also from the dorsal aspect.The secure fixing of the articulator upper section
also prevents an unintentional separation of the
articulator even if the centric locks are open.The movements of the articulator are exactly
guided by spring elements.
High EndPROTAR evo 7PROTAR evo 9 ?="" border="0" height="119" width="175" />
?="" border="0" height="119" width="175" />
Saggital
Condylar
pathadjustable
-10 bis 90° (FH)
-25 bis 75° (CE)adjustable
-10 bis 90° (FH)
-25 bis 75° (CE)Horizontal
Condylar path
(Bennett)adjustable
0 - 30°adjustable
0-30°Horizontal
Condylar path
(Iss)0 - 1,5 mm0 - 1,5 mmHorizontal
Condylar path
Shift angleOptional (with accessorie 622.1111)
-20 up to 20°0°Protrusion0 - 1,5 mm (adjustable)0 - 6 mm (einstellbar)Retrusion0 - 1 mm (adjustable)0 - 1 mm (einstellbar)Distraction0 - 1,5 mm (adjustable)0 - 6 mm (einstellbar)Occlusal CorrectionsMinimumMinimum
What limits should be observed?
MAK value: Average workplace concentration (duration of exposure 8
hours per working day; excluding carcinogenic substances according
to § 15a GefStoffV); for quartz, this is 0.00015 g /m3
of room air; for plaster and gold, the figure is 0.008 g/m3.
Jig for average value articulator mounting (0.622.1171)
With the aid of the articulator mounting jig, both toothed/partially
toothed and edentulous mandibular casts can be mounted
in the articulator using the average value principles.
Unbeatable Combination
Working together with the electronic
measuring system KaVo ARCUSdigma,
the KaVo articulator PROTARevo
offers unbeatable efficiency and precision.
Mounting plate for PROTAR articulators without split case (1.001.0889)
Mounting plate for PROTAR articulators without mounted split cast. The plaster cast can easily be separated from the mounting plate. Precise repositioning possible. 10 units in each package.
Articulator - order numbers
Evo 2
3PS magnetic fixing
1.002.3305
Evo 3
3PS magnetic fixing
split cast
1.002.3308
1.002.3309
Evo 5
3PS magnetic fixing
split cast
1.002.3312
1.002.3313
Evo 5b
3PS magnetic fixing
split cast
1.002.3316
1.002.3317
Evo 7
3PS magnetic fixing
split cast
1.002.3320
1.002.3321
Evo 9
3PS magnetic fixing
split cast
1.002.3324
1.002.3325
Evo Digma
split cast
1.005.4121
Educational material
Video of he PROTAR System
Introduction to the handling of the PROTAR articulator and the ARCUS facial bow. German: VHS/PAL (1000 4154). English: VHS/PAL (1000 4155) and VHS/NTSC (1.000.4156). Additional languages upon request
Threaded inserts (1.001.0886)
Metal plates for producing plaster split plates, with threads. Suitable for plaster mounting set with screw fastening. 20 units in each package.
Light weight
Due
to the new design and effective use
of materials, it was possible to reduce
the weight by up to 25%, depending
on model.
As a result, the handling is greatly
simplified.
Maxillary cast positioner (0.622.1781)
With the aid of the maxillary cast positioner, both toothed/partially toothed and edentulous maxillary casts can be mounted in the articulator according to the average value principle. Preferably used for the APF NT method.
Occlusion inclination indicator (0.622.2071)
This accessory serves as a setup aid for the edentulous mandibular prosthesis. Preferably used for the APF NT method. The position of the occlusal plane is determined here by reference points of the edentulous maxillary cast.
Easy maintenance
Smooth surfaces with distinctly less
edges and corners enable first class
removal of, for example plaster, and
greatly simplify the problems of maintenance.
Plaster mounting plates (1.001.0888)
Metal plates for the production of plaster split plates, without thread. Suitable for plaster mounting set with magnet fastening. 20 units in each package.
Parting agent Polysep
Plaster casts separate more easily from the mounting plates. Plaster exhibits less adhesion to the articulator.
250ml (0.622.4442)
1000ml (0.622.4452)
Facebow ARCUS
The position of the upper jaw can
be directly transferred to the articulator
by use of the ARCUS facebow
Plaster mounting set (0.622.1121)
Plaster plate with integrated split cast. With this plaster
plate, a split cast check can be performed. The plaster
plates can be produced in any thicknesses.
Plaster mounting sleeves (1.000.3102)
Two plaster mounting sleeves of different heights facilitate plaster mounting in the articulator.
Proved world wide
The precise KaVo Split Cast is a prerequisite
so that the model with the prosthetic
work can be sent without the articulator. Your
valuable piece of equipment remains in your hands.
3PS
New style mounting plates, made of metal with magnetic attachment.
Expandable for coordination in the laboratory.
Incisal pin E (0.622.1181)
Included in the PROTAR delivery.
Incisal pin P (0.622.1791)
INOX incisal pin with moulded-on ball for forming an individual incisal guide. Possibility for precise setting in 5/100 steps. Secured to prevent falling.
Support pin T (0.622.1891)
INOX support pin with moulded-on ball for forming an individual incisal guide. Possibility for precise setting in 5/100 steps. Secured to prevent falling. The curvature improves visualisation of the incisal edge.
Incisal indicator (0.622.1021)
Serves as an orientation tool. Its tips indicates the incisal point of the mandible. Bonwill's triangle 110 mm.
Adjustable incisal table (1.003.7600)
The fully adjustable incisal table controls the articulator as an anterior guide element. Before grinding, the anterior tooth guidance and canine guidance is transferred to the adjustable incisal table.
Incisal table
Plan (0.622.1912), 10° (0.622.1922), 20° (0.622.1932), 30° (0.622.1942), 40° (0.622.1952), 50° (0.622.1962).
The fully prefabricated incisal table controls the articulator as an anterior guide element. An incisal table is selected depending on the existing guide angle. The flat incisal table is also for creating individual anterior guides.
With set-up calotte, complete (0.622.6214)
A mandibular total prosthesis is set up using the setup calotte. All of the reference points are taken from the mandibular model. If a divided wax rim already exists, the calotte is aligned according with reference to the occlusal plane determined in the patient. Including long calotte.
Calotte holder (0.622.1161)
P. 0.622.6214.
Bite fork support (0.622.0901)
P. 0.622.6214.
Calotte, short (0.622.1201)
Defines the compensation curve in the total prosthetics without anterior teeth and canines.
Calotte, long (0.622.1211)
Defines the compensation curve in the total prosthetics with anterior teeth and canines.
PDR inserts (0.622.1001)
Can be used with the PROTAR 7 or 9. Enables 0-6 mm distraction (D), 0-6 mm protrusion (P) and 0-1 mm retrusion (R).
Shift angle insert (0.622.1111)
Can be used with the PROTAR7. Enables precise movement on the work side. 0-20° lateroretrusion, 0-20° lateroprotrusion.
Model table (0.625.0770)
Model table for measuring and milling. Uses for conical and telescopic crowns.
Carrying case
Storage case for PROTARevo articulators and ARCUS facial bow.
KaVo LOGIcase (1.001.1511)
Your solution for the transport between the dental practice and the laboratory.
10 boxes (20 half shells)